Duct air conditioners with universal outdoor units FORT series

ROVER FORT duct indoor units are placed behind the false ceiling. Cooled air distribution is carried out through an air duct system. In this case an indoor unit and air ducts are hidden from eyes.

The return duct can be connected from the back of the unit or from the bottom depending on installation site.ROVER FORT duct  is easy to install.

Duct air conditioners with universal outdoor units of the FORT series are represented by models: 18 000 BTU (RU0ND18BE), 24 000 BTU (RU0ND24BE), 36 000 BTU (RU0ND36BD), 48 000 BTU (RU0ND48BD), 60 000 BTU (RU0ND60BD).

Functions and operating modes

  • Autorestart
  • Comfortable sleep
  • Automatic operation
  • "Warm Start"
  • Setting the timer
  • “I feel” function
  • Self-diagnosis
  • Volumetric airflow
  • Intelligent defrosting
  • Refractory electrical box

Technical parameters

Model complete set RU1ND18ABE RU1ND24ABE RU1ND36ABD RU1ND48ABD RU1ND60ABD
Capacity cooling kW 5.285 7.047 10.55 14.071 16.091
heating 5.561 7.627 11.713 16.13 17.562
Power supply ph/V/Hz 1/~(220±10%)/50 1/~(220±10%)/50 3/~(380-415)/50 3/~(380-415)/50 3/~(380-415)/50
Rated power input cooling kW 1.95 2.7 3.505 5.35 6.36
heating 1.65 2.23 3.435 4.815 5.54
Operating current cooling A 8.7 11.7 5.9 9.2 11.0
heating 7.3 9.7 5.7 8.3 9.3
SEER/SCOP 2.71/3.37 2.61/3.42 3.01/3.41 2.63/3.35 2.53/3.17
Energy class D/C D/B B/B D/C E/D
Air flow (max.) м3/h 1 020/830/740 1 350/1 150/950 1 804/1 372/1 149 2 150/1 800/1 400 2 400/1 850/1 490
Static pressure Pa 25 (0-60) 25 (0-80) 37 (0-160) 50 (0-160) 50 (0-160)
Noise level indoor unit dB(A) 38/41/44 34/38/41 38/40/47 42/45/48 44/47/52
outdoor unit 58.5 60 62.5 62 61.5
Refrigerant type R410А R410А R410А R410А R410А
Refrigerant charge* kg 1.3 2.0 2.85 3.3 3.3
Parameters of refrigerant pipes pipe diameter liq. 1/4'' 3/8'' 3/8'' 3/8'' 3/8''
gas 1/2'' 5/8'' 3/4'' 3/4'' 3/4''
length (max) м 25 25 30 50 50
height difference (max) 15 15 20 30 30
Drain pipe (outside diameter) mm ø25 ø25 ø25 ø25 ø25
Air switch** nominal current A 25 32 25 32 32
Power cable (to IDU) n×мм² 3×2.5 3×2.5 - 5×2.5 5×2.5
Power cable (to ODU) - - 5×2.5 - -
Interblock cable 3×2.5+2×1.0+2×0.75 3×2.5+3×1.0+2×0.2 3×1.5+3×1.0 5×2.5+3×1.0 5×2.5+3×1.0
Dimensions
(width × height × depth)
indoor unit mm 880×210×674 1 100×249×774 1 100×249×774 1 200×300×874 1 200×300×874
outdoor unit 805×554×330 890×673×342 946×810×410 900×1 170×350 900×1 170×350
Package dimensions
(width × height × depth)
indoor unit mm 1 070×280×725 1 305×305×805 1 305×305×805 1 405×365×915 1 405×365×915
outdoor unit 915×615×370 995×740×398 1 090×875×500 1 032×1 307×443 1 032×1 307×443
ODU installation dimensions mm 511×317 663×348 673×403 590×378 590×378
Weight (net / gross) indoor unit kg 23.4/28.8 32.6/39.0 32.2/39.4 46.0/54.5 46.0/54.4
outdoor unit 37.8/40.4 52.9/55.9 73.0/77.5 98.6/109.3 99.7/111.2

 

* The amount of freon is indicated for the pipe length of no more than 5 m. With an increase of the pipe length, it is necessary to charge the additional refrigerant at the rate of 15 g per 1 m for the 1/4″liquid pipe and 30 g per 1 m for the 3/8″liquid pipe.

** Cut-off current is not less than 7 In (In - rated current), leakage current is not more than 30mA, shutdown characteristic is «C». It is allowed to install the circuit breaker and RCD with the same capacity in series.

The table shows data for temperature conditions in accordance with ISO 5151-94:
- cooling mode inside 27 °C (DB)/19 °C (WB), outside 35 °C (DB)/24 °C (WB)
- heating mode inside 20 °C (DB)/15 °C (WB), outside 7 °C (DB)/6°C (WB)